gryphonprojects

Scope of Work and Specification – Electrical

Trade

Electrical

Project

Bathroom Renovation

Location

Client

Date

1. Scope of Work

  1. Isolate and make safe existing electrical circuits servicing the bathroom area.
  2. Remove and decommission existing electrical fittings and accessories including lights, fans, power points, and heat lamps.
  3. Supply and install new electrical cabling, junction boxes, and conduits as required for new fixture layout.
  4. Install and connect new light fittings, exhaust fans, mirror lighting, and power points (including GPOs in vanity or cabinetry).
  5. Install and connect new heated towel rail and/or underfloor heating (if specified).
  6. Test and certify all new installations to ensure safe operation and compliance with current regulations.
  7. Provide switchboard updates (e.g. RCBO or RCD installation) if required due to increased bathroom load or circuit upgrades.
  8. Coordinate with other trades to ensure rough-in and fit-off timing aligns with tiling, cabinetry, and painting stages.

Materials and Fixtures

All fittings and fixtures shall be as per the client’s selection schedule. The electrician must confirm compatibility and load ratings before installation.

Where selections are pending, provisional allowances or contractor-supplied standard fittings shall be noted.

Fixture/ItemDescription / BrandSupplied By (Client / Electrician)
Ceiling Light[Insert][Insert]
Exhaust Fan[Insert][Insert]
Power Point (GPO)[Insert][Insert]
Mirror Light[Insert][Insert]
Heated Towel Rail[Insert][Insert]
Other[Insert][Insert]
Other[Insert][Insert]

Compliance and Standards

  1. All work shall comply with the latest version of AS/NZS 3000 (Wiring Rules) and relevant state electrical safety regulations.
  2. All electrical work must be carried out by a licensed electrician and a Certificate of Electrical Safety must be issued upon completion.
  3. All bathroom electrical work must meet IP rating requirements based on zone classification (e.g., IPX4 in zone 1).
  4. All circuits supplying bathroom fixtures must be protected by RCDs in accordance with the NCC and AS/NZS 3000.
  5. Any penetrations made in fire-rated or waterproof areas must be sealed as per code.

Testing and Commissioning

1. All circuits shall be insulation resistance tested prior to connection.
2. All fittings must be tested for correct polarity, earth continuity, and RCD function.
3. All lighting and appliances shall be tested for correct operation.
4. Certificate of Electrical Safety shall be provided to the client or builder on completion.

Coordination and Site Conditions

1. The electrician shall liaise with the builder or site supervisor to confirm locations of all switches, lights, fans, and outlets.
2. Electrician shall ensure rough-in is complete prior to wall sheeting or tiling works.
3. Fit-off shall be coordinated after cabinetry, tiling, and painting works are complete.
4. Site must be kept tidy, and all debris and packaging removed at the end of works.

Exclusions

1. Works outside the defined bathroom renovation area unless explicitly stated.
2. Installation of smart home systems, AV equipment, or non-standard data wiring.
3. Provision of fixtures unless specifically nominated.
4. Alterations to switchboard unless triggered by compliance upgrades.

Authorised By:

Accepted By: